Ok so I have been having issues with the fan, It will not run when the Engine Coolant Temperature ECT is grounded. I traced all connections and there are no open circuits. The coolant tempertaure indicator will not light when the engine starts. This will happen when the key switch is not plugged in, I tested the conections on the key switch and believe them to be faulty. I have attached a picture of the wiring diagram to this post but I think the wire color designations are incorrect. On the 450 there is a Green wire, a red wire and two black wires one with a white tracer.
The wiring diagram though shows a green wire paired with a black wire with white tracer and a Red wire paired with a red wire with white a tracer. I think this red wire with white tracer in fact should be a solid black wire. I removed the key switch and shorted the Red wire with the black wire to trick the 450 into thinking the key switch is plugged in. The 450 will start but still do not get the light to come on for a few seconds or get the fan to run.
The wiring diagram though shows a green wire paired with a black wire with white tracer and a Red wire paired with a red wire with white a tracer. I think this red wire with white tracer in fact should be a solid black wire. I removed the key switch and shorted the Red wire with the black wire to trick the 450 into thinking the key switch is plugged in. The 450 will start but still do not get the light to come on for a few seconds or get the fan to run.